A PHP Error was encountered

Severity: Warning

Message: fopen(/tmp/ci_session103b3595f7b50282979cd76695fc5149d2cc40c3): failed to open stream: Disk quota exceeded

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /home/hitechzo/public_html/lab-compare.com/application/controllers/Home.php
Line: 10
Function: __construct

File: /home/hitechzo/public_html/lab-compare.com/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /tmp)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /home/hitechzo/public_html/lab-compare.com/application/controllers/Home.php
Line: 10
Function: __construct

File: /home/hitechzo/public_html/lab-compare.com/index.php
Line: 315
Function: require_once

Overview

Single Beam UV VIS SpectrophotometerTRSUV-601 is a versatile device with blazed holographic gratings and an 8-inch multi-color touch-screen that allows for the setting and viewing of parameters with such a wavelength range of 190 to 1100 nm and then a frequency band bandwidth of 2 nm. The automated 8-position cuvette holder makes the operation mode easier. It has a photometric accuracy of 0.3 % T, 0.002Abs (0 to 0.5A), and a range of 0.0 to 200.0 % T, -0.301 to 4.000A, and 0.000 to 9999 C. It performs admirably in both qualitative and quantitative testing and has a stray light of ≤ 0.03%..

Specifications :

Photometry Split Beam
Monochromatic Type Czerny-Turner
Focal Length 160 mm
Grating 1200 lines/mm
Detector Silicon Photocell
Spectrum Bandwidth 2 nm
Wavelength Range 190 to 1100 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Repeatability ≤ 0.2 nm
Photometric Range 0.0 to 200.0% T -0.301 to 4.000A 0.000 to 9999C
Photometric Accuracy ± 0.3% T ± 0.002Abs (0 to 0.5A) ± 0.004Abs (0.5 to 1A)
Photometric Repeatability ≤ 0.15% T 0.001Abs (0 to 0.5A) 0.002Abs (0.5 to 1A)
Wavelength Scanning Speed Fast, medium, slow
Baseline Flatness ≤ ± 0.002 A
Stray Light ≤ 0.03% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
Noise 100%(T) noise ≤ 0.15% (T), 0% (T) noise ≤ 0.1% (T)
Baseline Drift ± 0.0009 Abs / h (250 nm and 500 nm after preheat warm up for 2 hours )
Power AC 220 V± 22 V, 50 Hz± 1 Hz, 200 W
COM Port USB
Packing Size 740 mm×630 mm×450 mm
Weight 0.21m³, 35kg

Features :

  • 8-inch multi-color touch-screen, advanced user interface, powerful functions, and simple operation
  • It uses a split-beam survey optical system as well as a blazed holographic display
  • Scanning the entire spectrum
  • Linear regression analysis
  • Extensive frequency band scanning
  • Persistence of time-based kinetics
  • Measurement of multiple wavelengths
  • The zero and full scales are automatically adjusted. A USB port is included
  • Gratings they have exceptional test precision and very competitive pricing
  • The automated 8-position cuvette holder makes operation easier in each measurement mode
  • With its powerful functions, the equipment performs admirably in both qualitative and quantitative testing